(937) 372-1445

Buyer's Inspection Service

Dayton, Ohio Home Inspectors

  • Home Inspections
    • The Inspection
    • Walk Through Inspection
    • New Construction
    • Inspection Report
    • Testing & Evaluation Options
    • Pricing
  • Commercial
    • The Inspection
    • Walk Through Inspection
    • The Inspection Report
    • Testing & Evaluation Options
    • Pricing
  • Consultation
    • Consultation Service
      • The Consult
      • Post Consultation
      • Pricing
    • Maintenance
      • Benefits
      • The Inspection
      • The Report
      • Pricing
  • Information
    • Choosing Inspectors
    • Comparing Inspectors
    • Licensed Inspectors
    • Walk Through Inspection
    • Sample Report
    • Additional Testing Options
  • About
    • The Inspection Team
    • How We Started
    • Our Home Inspection Guarantee
  • FAQ
    • Blog
    • Contractors
  • Contact Us
  • Reviews
You are here: Home / Frequently Asked Questions / Electrical / Federal Pacific Panels

Federal Pacific Panels

There has been and continues to be a lot of discussion about the safety of Federal Pacific (FPE) “Stab-Lok” circuit breaker panels and the fact that they may have inherent defects. The result of the defect has linked them to numerous electrical fires.

There is no supporting evidence from any government agency or regulatory authority stating that these FPE panels are unsafe and should be replaced. There has not been a recall by the consumer product safety commission. If you have one of these FPE panels or intend to purchase a home that has one of these FPE panels, we suggest that you talk with your electrician and decide what is right for you and your family.

As a Home Inspector, this information puts us in a very difficult situation when we perform a whole house Home Inspection. These FPE breaker panels do “perform their intended function” when performing a visual inspection. The panel does not “initiate” an unsafe condition, which leaves us in the precarious position of knowing that a latent problem may exist in a breaker panel that we check off as “performing intended function”.

The following has been said about Federal Pacific Electric “Stab-Lok” panels:

That these panels pose a latent threat and could be a hazard. The circuit breakers may fail to trip in the case of an overload or short-circuit. A circuit breaker that fails to trip could cause a fire or personal injury.

The problem with Federal pacific breaker panels is that some of the double pole 220 volt circuit breakers and some of the single pole 120 volt circuit breakers may not operate as intended if overloaded. A good breaker trips turning off the power to that circuit if it is overloaded. Federal Pacific breakers appear not to trip every time which could result in a fire.
Published reports of tests conducted on FPE two pole 220 volt circuit breakers indicate that under certain conditions one leg/pole may attempt to trip the breaker. The result is a circuit that stays live, and a circuit breaker that has been compromised and when reset, will not trip the next time it is under any excessive load.
In many instances the breakers are loose and fall out when the cover is removed. Loose contacts can also be the cause of arcing which is a spark that can result in a fire. Unfortunately these panels appear to work perfectly during normal operation allowing electricity to flow without any problems or symptoms giving a false sense of security.

The real question for you is, what will your panel do if it is overloaded or there is a short in the wiring?

The Consumer Product Safety Commission (CPSC) did conduct product testing of these FPE breakers and found that their failure rates were significant. The CPSC’s advice concerning these panels is for consumers to avoid overloading circuits as well as to turn off and have examined any devices that are causing the circuit breakers to trip. (This is easier said than done and defeats the whole point for having the breaker.)

Federal Pacific Electric’s statement in response to this problem is cautious in tone:
“FPE breakers will trip reliably at most overload levels“.

It should be noted that Federal Pacific is no longer in business.

Aftermarket breakers are available for these panels. Most of these panels are large and had a lot of circuits and the cost of replacing all the breakers is often more than the cost of installing a new panel and to anyone buying your property at a later stage, it still has a Federal Pacific (defective) panel.

There was a class action lawsuit initiated. We believe that the lawsuit has been discontinued. The attorney’s phone number is no longer in service.

Based on the above information and in the interests of safety,
we recommend that our clients consult with a qualified electrician and discuss the replacement of these panels.

Inspectors’ Recent Posts


Gas Line Dirt Legs

March 28, 2025 By David Roche

Gas and particularly natural gas piping may have traces of sediment or particulates in it, especially if work has been done to the underground piping under the street. To trap any contaminates before they flow into the appliance, blocking the burner and creating problems for the home owner a series of dirt legs are installed. […]Read More about Gas Line Dirt Legs

Thermostat Placement Is Crucial

March 13, 2025 By David Roche

A badly placed thermostat plays havoc with the heating and cooling of a house. In this case the wall light creates a warm zone beside the thermostat causing it to register hotter than the rest of the house. This means that it reaches what it registers as the set temperature shutting the furnace down before […]Read More about Thermostat Placement Is Crucial

Bath Overflow Loose

January 25, 2025 By David Roche

All too often the overflow on the bathtub is loose or worse yet loose and the gasket damaged. If the bath is filled up to the overflow and it is loose the water will go down behind the tub which if it’s on the second floor could damage the ceiling. The water can also create […]Read More about Bath Overflow Loose

Bonding Gas Piping

January 8, 2025 By David Roche

A bonding wire is often mistaken for a ground wire, it does not go to ground but back to the electric panel. When it is connected to black iron *(steel)* piping the paint under the clamp must be removed with a rasp or sandpaper to make a good contact, paint reduces the contact rendering the […]Read More about Bonding Gas Piping

High Efficiency Furnaces In Attic

December 31, 2024 By David Roche

High efficiency furnaces recognisable by the white PVC flue pipe, installed in an unheated attic is not your best choice of location, it may be the only place to put it which does not change the fact that it is not ideal. Yes, many builders and furnace installers are installing them in the attic without […]Read More about High Efficiency Furnaces In Attic

Buyer's Inspection Service

Mailing Address
P.O. Box 707
Xenia, OH 45385

Address (No walk-ins)
120 West Second Street
Dayton, OH 45402

Clebrating 26 Years of Business
ASHI - American Society of Home Inspectors
InterNACHI - International Association of Certified Home Inspectors
ASI - American Inspectors Society

Connect with Us

  • facebook
  • youtube
  • phone
  • email

NAHI - National Association of Home Inspectors, Inc.

About Us

We are local, not a franchise that "self certifies" its Inspectors. We have earned the highest level of licensure available in the country and are ready to give you the Inspection you deserve. Our referrals and reviews tell us that we are really detailed, strive to deliver a quality product and are great at explaining what we find.

Customer Reviews

Google Rating
Based on 562 reviews
Facebook Rating
Based on 25 reviews
Yelp Rating
Based on 13 reviews

(937) 372-1445
© 2025 Buyer’s Inspection Service · Legal Disclaimer